Logging Level
Logging level
determines how many messages the
Content Engine
outputs to the log file. For general information about this, see
Configure Logging Levels.
Logging level can be set in three different places:
-
In the
trace.properties
file. General, permanent logging level settings should be made here. -
In the configuration layers. You can set special logging level settings for a particular component in that component's
.properties
file. Any settings made here will override the general settings intrace.properties
and are permanent. For general information about configuration layers, see Configuring The Content Engine. -
Using the
escenic-admin
application's View the logging levels option (see Configure Logging Levels). Any settings made here will override settings made intrace.properties
and settings made in the configuration layers. The settings are, however, only temporary: they will disappear when the Content Engine is restarted.
In a production environment you are recommended to set the general
logging level to ERROR
.